TIMER0¶
Timer¶
Provides a generic Timer core.
The Timer is implemented as a countdown timer that can be used in various modes:
Polling : Returns current countdown value to software
One-Shot: Loads itself and stops when value reaches
0
Periodic: (Re-)Loads itself when value reaches
0
en
register allows the user to enable/disable the Timer. When the Timer is enabled, it is
automatically loaded with the value of load register.
When the Timer reaches 0
, it is automatically reloaded with value of reload register.
The user can latch the current countdown value by writing to update_value
register, it will
update value
register with current countdown value.
To use the Timer in One-Shot mode, the user needs to:
Disable the timer
Set the
load
register to the expected duration(Re-)Enable the Timer
To use the Timer in Periodic mode, the user needs to:
Disable the Timer
Set the
load
register to 0Set the
reload
register to the expected periodEnable the Timer
For both modes, the CPU can be advertised by an IRQ that the duration/period has elapsed. (The
CPU can also do software polling with update_value
and value
to know the elapsed duration)
Register Listing for TIMER0¶
Register |
Address |
---|---|
TIMER0_LOAD¶
Address: 0xf0007800 + 0x0 = 0xf0007800
Load value when Timer is (re-)enabled. In One-Shot mode, the value written to this register specifies the Timer’s duration in clock cycles.
TIMER0_RELOAD¶
Address: 0xf0007800 + 0x4 = 0xf0007804
Reload value when Timer reaches
0
. In Periodic mode, the value written to this register specify the Timer’s period in clock cycles.
TIMER0_EN¶
Address: 0xf0007800 + 0x8 = 0xf0007808
Enable flag of the Timer. Set this flag to
1
to enable/start the Timer. Set to0
to disable the Timer.
TIMER0_UPDATE_VALUE¶
Address: 0xf0007800 + 0xc = 0xf000780c
Update trigger for the current countdown value. A write to this register latches the current countdown value to
value
register.
TIMER0_VALUE¶
Address: 0xf0007800 + 0x10 = 0xf0007810
Latched countdown value. This value is updated by writing to
update_value
.
TIMER0_EV_STATUS¶
Address: 0xf0007800 + 0x14 = 0xf0007814
This register contains the current raw level of the zero event trigger. Writes to this register have no effect.
Field |
Name |
Description |
---|---|---|
[0] |
ZERO |
Level of the |
TIMER0_EV_PENDING¶
Address: 0xf0007800 + 0x18 = 0xf0007818
When a zero event occurs, the corresponding bit will be set in this register. To clear the Event, set the corresponding bit in this register.
Field |
Name |
Description |
---|---|---|
[0] |
ZERO |
1 if a zero event occurred. This Event is triggered on a falling edge. |
TIMER0_EV_ENABLE¶
Address: 0xf0007800 + 0x1c = 0xf000781c
This register enables the corresponding zero events. Write a
0
to this register to disable individual events.
Field |
Name |
Description |
---|---|---|
[0] |
ZERO |
Write a |